MODULAR UNITS for POLYMERIZATION of SULFUR TA-PMS 5000
Table 1. Technical characteristics of the module heating and polymerization of sulfur
№
|
parameter name |
The value of the parameter |
1 | Rated capacity, t / h (-25 … + 5%) |
5 |
2 | The volume of the hopper, m3 |
1,8 |
3 | Schieber boot the tuft of the electric power, kW |
3,2 |
The total installed capacity. kW | ||
4 | Mixers:-quantity, pcs. — Power consumption, kW |
3 4 |
5 | Dimensions of the heating and polymerization vessel mm |
6000х2400 х2600 |
Table 2. Specifications of thermal oil heating module
Name |
Units |
value |
||
Rated heating capacity |
MW MW (Gcal/h) |
0,45 (0,39) |
||
Efficiency | % |
86 |
||
Permissible operating temperature of the coolant |
°С |
240 |
||
The maximum coolant supply pressure |
MPa |
0,6 |
||
The nominal coolant consumption | m3/h
|
25 |
||
Coolant — oil AMT-300 TU 38.401-58-358-2005 | ||||
Burner unit — gas burner Weishaupt WG 40 N / 1-A, App. ZM-LN | ||||
Fuel — natural gas in accordance with GOST 5542-87 | ||||
Estimated gas consumption
(With calorific value of 33.5 MJ / Nm3) |
light duty |
m3 / h |
24,42 |
|
big load |
54,95 |
|||
Connecting gas pressure |
kPa |
103) |
||
Estimated aerodynamic resistance of the heating chamber |
Pa |
17,3 |
||
The volume of coolant, filled to the heater |
m3 |
0,58 |
||
Volume of the receiving container |
m3 |
1,5 |
||
power | mains voltage |
v |
~ 400 |
|
control voltage |
v |
~ 230 |
||
3L / N / PE: five-wire line connection of the neutral conductor N |
frequency |
Гц |
50 |
|
necessarily |
Grounding system type | TN-S | ||
Installed electrical power kW |
13,6 |